#+TITLE: Estimating the end-to-end energy consumption of low-bandwidth IoT applications for WiFi devices
|
|
|
|
#+EXPORT_EXCLUDE_TAGS: noexport
|
|
#+STARTUP: hideblocks
|
|
#+OPTIONS: H:5 author:nil email:nil creator:nil timestamp:nil skip:nil toc:nil ^:nil
|
|
#+LATEX_CLASS: llncs
|
|
#+LATEX_HEADER: \usepackage{hyperref}
|
|
#+LATEX_HEADER: \usepackage{booktabs}
|
|
#+LATEX_HEADER: \usepackage{subfigure}
|
|
#+LATEX_HEADER: \usepackage{graphicx}
|
|
#+LATEX_HEADER: \usepackage{xcolor}
|
|
#+LATEX_HEADER: \author{
|
|
#+LATEX_HEADER: Loic Guegan and
|
|
#+LATEX_HEADER: Anne-Cécile Orgerie\\
|
|
#+LATEX_HEADER: }
|
|
#+LATEX_HEADER: \institute{Univ Rennes, Inria, CNRS, IRISA, Rennes, France\\
|
|
#+LATEX_HEADER: Emails: loic.guegan@irisa.fr, anne-cecile.orgerie@irisa.fr
|
|
#+LATEX_HEADER: }
|
|
|
|
|
|
|
|
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\newcommand{\hl}[1]{\textcolor{red}{#1}}
|
|
#+END_EXPORT
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{abstract}
|
|
Information and Communication Technology takes a growing part in the
|
|
worldwide energy consumption. One of the root causes of this increase
|
|
lies in the multiplication of connected devices. Each object of the
|
|
Internet-of-Things often does not consume much energy by itself. Yet,
|
|
their number and the infrastructures they require to properly work
|
|
have leverage. In this paper, we combine simulations and real
|
|
measurements to study the energy impact of IoT devices. In particular,
|
|
we analyze the energy consumption of Cloud and telecommunication
|
|
infrastructures induced by the utilization of connected devices, And
|
|
we propose an end-to-end energy consumption model for these devices.
|
|
\end{abstract}
|
|
#+END_EXPORT
|
|
|
|
|
|
* Introduction
|
|
In 2018, Information and Communication Technology (ICT) was estimated
|
|
to absorb around 3% of the global energy consumption
|
|
\cite{ShiftProject}. This consumption is estimated to grow at a rate
|
|
of 9% per year \cite{ShiftProject}. This alarming growth is explained
|
|
by the fast emergence of numerous applications and new ICT
|
|
devices. These devices supply services for smart building, smart
|
|
factories and smart cities for instance. Through connected sensors
|
|
producing data, actuators interacting with their environment and
|
|
communication means -- all being parts of the Internet of Things (IoT)
|
|
-- they provide optimized decisions.
|
|
|
|
This increase in number of devices implies an increase in the energy
|
|
needed to manufacture and utilize them. Yet, the overall energy bill
|
|
of IoT also comprises indirect costs, as it relies on computing and
|
|
networking infrastructures that consume energy to enable smart
|
|
services. Indeed, IoT devices communicate with Cloud computing
|
|
infrastructures to store, analyze and share their data.
|
|
|
|
In February 2019, a report by Cisco stated that ``IoT connections will
|
|
represent more than half (14.6 billion) of all global connected
|
|
devices and connections (28.5 billion) by 2022" \cite{Cisco2019}. This
|
|
will represent more than 6% of global IP traffic in 2022, against 3%
|
|
in 2017 \cite{Cisco2019}. This increasing impact of IoT devices on
|
|
Internet connections induces a growing weight on ICT energy
|
|
consumption.
|
|
|
|
The energy consumption of IoT devices themselves is only the top of
|
|
the iceberg: their use induce energy costs in communication and cloud
|
|
infrastructures. In this paper, we estimate the overall energy
|
|
consumption of an IoT device environment by combining simulations and
|
|
real measurements. We focus on a given application with low bandwidth
|
|
requirement and we evaluate its overall energy consumption: from the
|
|
device, through telecommunication networks, and up to the Cloud data
|
|
center hosting the application. From this analysis, we derive an
|
|
end-to-end energy consumption model that can be used to assess the
|
|
consumption of other IoT devices.
|
|
|
|
While some IoT devices produce a lot of data, like smart vehicles for
|
|
instance, many others generate only a small amount of data, like smart
|
|
meters. However, the scale matters here: many small devices can end up
|
|
producing big data volumes. As an example, according to a report
|
|
published by Sandvine in October 2018, the Google Nest Thermostat is
|
|
the most significant IoT device in terms of worldwide connections: it
|
|
represents 0.16% of all connections, ranging 55th on the list of
|
|
connections \cite{Sandvine2018}. As a comparison, the voice assistants
|
|
Alexa and Siri are respectively 97th and 102nd with 0.05% of all
|
|
connections \cite{Sandvine2018}. This example highlights the growing
|
|
importance of low-bandwidth IoT applications on Internet
|
|
infrastructures, and consequently on their energy consumption.
|
|
|
|
In this paper, we focus on IoT devices for low-bandwidth applications
|
|
such as smart meters or smart sensors. These devices send few
|
|
data periodically to cloud servers, either to store them or to get
|
|
computing power and take decisions. This is a first step towards a
|
|
comprehensive characterization of the global IoT energy
|
|
footprint. While few studies address the energy consumption of
|
|
high-bandwidth IoT applications \cite{li_end--end_2018}, to the best
|
|
of our knowledge, none of them targets low-bandwidth applications,
|
|
despite their growing importance on the Internet infrastructures.
|
|
|
|
Low-bandwidth IoT applications, such as the Nest Thermostat, often
|
|
relies on sensors powered by batteries. For such sensors, reducing
|
|
their energy consumption is a critical target. Yet, we argue that
|
|
end-to-end energy models are required to estimate the overall impact
|
|
of IoT devices, and to understand how to reduce their complete energy
|
|
consumption. Without such models, one could optimize the consumption
|
|
of on-battery devices at a heavier cost for cloud servers and
|
|
networking infrastructures, resulting on an higher overall energy
|
|
consumption. Using end-to-end models could prevent these unwanted
|
|
effects.
|
|
|
|
Our contributions include:
|
|
- a characterization of low-bandwidth IoT applications;
|
|
- an analysis of the energy consumption of a low-bandwidth IoT
|
|
application including the energy consumption of the WiFi IoT device
|
|
and the consumption induced by its utilization on the Cloud and
|
|
telecommunication infrastructures;
|
|
- an end-to-end energy model for low-bandwidth IoT applications
|
|
relying on WiFi devices.
|
|
|
|
The paper is organized as follows. Section \ref{sec:sota} presents the
|
|
state of the art. The low-bandwidth IoT application is characterized
|
|
in Section \ref{sec:usec}, and details on its architecture are
|
|
provided in Section \ref{sec:model}. Section \ref{sec:eval} provides
|
|
our experimental results combining real measurements and
|
|
simulations. Section \ref{sec:discuss} discusses the key findings an
|
|
the end-to-end energy model. Finally, Section \ref{sec:cl} concludes
|
|
this work and presents future work.
|
|
|
|
|
|
|
|
* Related Work
|
|
#+LaTeX: \label{sec:sota}
|
|
** Energy consumption of IoT devices
|
|
The multiplication of smart devices and smart applications pushes the
|
|
limits of Internet: IoT is now used everywhere for home automation,
|
|
smart agriculture, e-health, smart cities, logistics, smart grids,
|
|
smart buildings, etc. \cite{Wang2016,Ejaz2017,Minoli2017}. IoT devices
|
|
are typically used to optimize processes and the envisioned
|
|
application domains include the energy distribution and management. It
|
|
can for instance help the energy management of product life-cycle
|
|
\cite{Tao2016}. Yet, few studies address the impact of IoT itself on
|
|
global energy consumption \cite{jalali_fog_2016,li_end--end_2018} or
|
|
CO2 emissions \cite{Sarkar2018}.
|
|
|
|
The underlying architecture of these smart applications usually
|
|
includes sensing devices, cloud servers, user applications and
|
|
telecommunication networks. Concerning the computing part, the cloud
|
|
servers can either be located on Cloud data centers, on Fog
|
|
infrastructures located at the network edge, or on home gateways
|
|
\cite{Wang2016}. Various network technologies are employed by IoT
|
|
devices to communicate with their nearby gateway; either wired
|
|
networks with Ethernet or wireless networks: WiFi, Bluetooth, Near
|
|
Field Communication (NFC), ZigBee, cellular network (like 3G, LTE, 4G),
|
|
Low Power Wide Area Network (LPWAN),
|
|
etc. \cite{Samie2016,Gray2015}. The chosen technology depends on the
|
|
smart device characteristics and the targeted communication
|
|
performance. The Google Nest Thermostat can for instance use WiFi,
|
|
802.15.4 and Bluetooth \cite{Nest}. In this paper, we focus on WiFi as
|
|
it is broadly available and employed by IoT devices
|
|
\cite{Samie2016,ns3-energywifi}.
|
|
|
|
Several works aim at reducing the energy consumption of the device
|
|
transmission \cite{Andres2017} or improving the energy efficiency of
|
|
the access network technologies \cite{Gray2015}. An extensive
|
|
literature exists on increasing the lifetime of battery-based wireless
|
|
sensor networks \cite{Wang2016}. Yet, IoT devices present more
|
|
diversity than typical wireless sensors in terms of hardware
|
|
characteristics, communication means and data production patterns.
|
|
|
|
Based on real measurements, previous studies have proposed energy
|
|
models for IoT devices. Yet, these models are specific to a given kind
|
|
of IoT device or a given transmission technology.
|
|
Martinez et al. provide energy consumption measurements for wireless
|
|
sensor networks using SIGFOX transmissions and employed for
|
|
smart-parking systems \cite{Martinez2015}. Wu et al. implement an
|
|
energy model for WiFi devices in the well-known ns3 network simulator
|
|
\cite{ns3-energywifi}.
|
|
|
|
|
|
** Energy consumption of network and cloud infrastructures
|
|
IoT architecture rely on telecommunication networks and Cloud
|
|
infrastructures to provide services. The data produced by IoT devices
|
|
are stored and exploited by servers located either in Cloud data
|
|
centers or Fog edge sites. While studies exist on the energy
|
|
consumption of network and cloud infrastructures in general
|
|
\cite{Ehsan}, they do not consider the specific case of IoT devices.
|
|
To the best of our knowledge, no study estimates the direct impact of
|
|
IoT applications on the energy consumption of these infrastructures.
|
|
|
|
Most work focusing on energy consumption, Cloud architecture and IoT
|
|
applications tries to answer the question: where to locate data
|
|
processing in order to save energy
|
|
\cite{jalali_fog_2016}, to reduce the CO2 impact \cite{Sarkar2018}, or
|
|
to optimize renewable energy consumption \cite{li_end--end_2018}.
|
|
|
|
In both cases, the network and cloud infrastructures, attributing the
|
|
energy consumption to a given user or application is a challenging
|
|
task. The complexity comes from the shared nature of these
|
|
infrastructures: a given Ethernet port in the core of the network
|
|
processes many packets coming from a high number of sources
|
|
\cite{jalali_fog_2016}. Moreover, the employed equipment is not power
|
|
proportional: servers and routers consume consequent amounts of
|
|
energy while being idle
|
|
\cite{mahadevan_power_2009,li_end--end_2018}.
|
|
The power consumed by a device is divided into two parts: a dynamic
|
|
part that varies with traffic or amount of computation to process, and
|
|
a static part that is constant and dissipated even while being idle
|
|
\cite{Ehsan}. This static part implies that a consequent energy cost
|
|
of running an application on a server is due to the device being
|
|
simply powered on. Consequently, sharing these static energy costs
|
|
among all the concerned users requires an end-to-end model
|
|
\cite{li_end--end_2018}.
|
|
|
|
In this paper, we focus on IoT devices using WiFi transmission and
|
|
generating low data volumes. Our model, extracted from real
|
|
measurements and simulations, can be adapted to other kinds of devices
|
|
and transmission technologies.
|
|
|
|
|
|
|
|
* Characterization of low-bandwidth IoT applications
|
|
#+LaTeX: \label{sec:usec}
|
|
|
|
In this section, we detail the characteristics of the considered IoT
|
|
application. While the derived model is more generic, we focus on a
|
|
given application to obtain a precise use-case with accurate power
|
|
consumption measurements.
|
|
|
|
The Google Nest Thermostat relies on five sensors: temperature,
|
|
humidity, near-field activity, far-field activity and ambient light
|
|
\cite{Nest}. Periodical measurements, sent through wireless
|
|
communications on the Internet, are stored on Google data centers and
|
|
processed to learn the home inhabitants habits. The learned behavior
|
|
is employed to automatically adjust the home temperature managed by
|
|
heating and cooling systems.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=0.5\linewidth]{./plots/home.png}
|
|
\caption{Overview of IoT devices.}
|
|
\label{fig:IoTdev}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
Each IoT device senses periodically its environment. Then, it sends
|
|
the produced data through WiFi (in our context) to its gateway or
|
|
Access Point (AP). The AP is in charge of transmitting the data to the
|
|
cloud using the Internet. Figure \ref{fig:IoTdev} illustrates this
|
|
architecture. Several IoT devices can share the same AP in a
|
|
home. We consider low-bandwidth applications where devices produces
|
|
several network packets during each sensing period. The transmitting
|
|
frequency can vary from one to several packet sent per minute
|
|
\cite{Cisco2019}.
|
|
|
|
#+BEGIN_COMMENT
|
|
The IoT part is composed of an Access Point (AP), connected to several sensors using WIFI. In the
|
|
system, the IoT part is considered as the part where the system data are created. In fact, the
|
|
data life cycle start when the sensors records their respective local temperature at a frequency
|
|
$f$ and the local timestamp. Then, these data are transmitted through the network along with an
|
|
arbitrary sensor id of 128 bits. Finally, the AP is in charge to transmit the data to the cloud
|
|
using the network part.
|
|
|
|
The network part is considered as the medium that link the IoT part to the cloud. It is composed
|
|
of several network switches and router and it is considered to be a wired network.
|
|
|
|
#+END_COMMENT
|
|
|
|
We consider that the link between the AP and the Cloud is composed of
|
|
several network switches and routers using Ethernet as shown in Figure
|
|
\ref{fig:parts}. The number of routers on the path depends on the
|
|
location of the server, either in a Cloud data center or in a Fog site
|
|
at the edge of the network.
|
|
|
|
We assume that the server hosting the application data for the users
|
|
belongs to a shared cloud facility with classical service level
|
|
agreement (SLA). The facility provides redundant storage and computing
|
|
means as virtual machines (VMs). A server can host several VMs at the
|
|
same time.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=0.6\linewidth]{./plots/parts2.png}
|
|
\caption{Overview of the IoT architecture.}
|
|
\label{fig:parts}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
In the following, we describe the experimental setup, the results and
|
|
the end-to-end model. For all these steps, we decompose the overall
|
|
IoT architecture into three parts: the IoT device part, the networking
|
|
part and the cloud part, as displayed on Figure \ref{fig:parts}.
|
|
|
|
|
|
* Experimental setup
|
|
#+Latex: \label{sec:model}
|
|
In this section, we describe the experimental setup employed to
|
|
acquire energy measurements for each of the three parts of our
|
|
system model. The IoT and the network parts are modeled
|
|
through simulations. The Cloud part is modeled using real
|
|
servers connected to wattmeters. In this way, it is possible to
|
|
evaluate the end-to-end energy consumption of the system.
|
|
|
|
** IoT Part
|
|
In the first place, the IoT part is composed of several sensors connected to an Access Point (AP)
|
|
which form a cell. This cell is studied using the ns3 network
|
|
simulator. In the experimental scenario, we setup
|
|
between 5 and 15 sensors connected to the AP using WiFi 5GHz 802.11n. The node are placed
|
|
randomly in a rectangle of $400m^2$ around the AP which corresponds
|
|
to a typical use case for a home environment. All
|
|
the cell nodes employ the default WIFI energy model provided by ns3. The different
|
|
energy values used by the energy model are provided in Table 1. These parameters
|
|
were extracted from previous work\cite{halperin_demystifying_nodate,li_end--end_2018} On
|
|
IEEE 802.11n. Besides, we suppose that the energy source of each
|
|
nodes is not limited during the experiments. Thus each node
|
|
can communicate until the end of all the simulations.
|
|
|
|
As a scenario, sensors send 192 bits packets to the AP composed of: \textbf{1)} A 128 bits
|
|
sensors id \textbf{2)} A 32 bits integer representing the temperature \textbf{3)} An integer
|
|
timestamp representing the temperature sensing date. They are stored as time series. The data are
|
|
transmitted immediately at each sensing interval $I$ that we vary from 1s to 60s. Finally, the AP is in
|
|
charge of relaying data to the cloud via the network part.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{table}[]
|
|
\centering
|
|
\caption{Simulations Energy Parameters}
|
|
\label{tab:wifi-energy}
|
|
\subtable[IoT part]{
|
|
\begin{tabular}{@{}lr@{}}
|
|
Parameter & Value \\ \midrule
|
|
Supply Voltage & 3.3V \\
|
|
Tx & 0.38A \\
|
|
Rx & 0.313A \\
|
|
Idle & 0.273A \\ \bottomrule
|
|
\end{tabular}}
|
|
\hspace{0.3cm}
|
|
\subtable[Network part]{
|
|
\label{tab:net-energy}
|
|
\begin{tabular}{@{}lr@{}}
|
|
Parameter & Value \\ \midrule
|
|
Idle & 0.00001W \\
|
|
Bytes (Tx/Rx) & 3.4nJ \\
|
|
Pkt (Tx/Rx) & 192.0nJ \\ \bottomrule
|
|
\end{tabular}
|
|
}
|
|
\end{table}
|
|
#+END_EXPORT
|
|
|
|
** Network Part
|
|
The network part represents the a network section starting from the AP to the Cloud excluding the
|
|
server. It is also modeled into ns3. We consider the server to be 9 hops away from the AP with a
|
|
typical round-trip latency of 100ms from the AP to the server
|
|
\cite{li_end--end_2018}. Each node from the AP to the Cloud
|
|
is a network switch with static and dynamic network energy consumption. The first 8
|
|
hops are edge switches and the last one is consider to be a core router as mentioned in
|
|
\cite{jalali_fog_2016}. ECOFEN \cite{orgerie_ecofen:_2011} is used to model the energy
|
|
consumption of the network part. ECOFEN is an ns3 network energy module dedicated to wired
|
|
networks. It is based on an energy-per-bit and energy-per-packet
|
|
model for the dynamic energy consumption
|
|
\cite{sivaraman_profiling_2011,Serrano2015}, and it includes also a static energy consumption.
|
|
The different values used to instantiate the ECOFEN energy model for the
|
|
network part are shown in left part of Table 1 and come from previous work
|
|
\cite{cornea_studying_2014-1}.
|
|
|
|
** Cloud Part
|
|
Finally, to measure the energy consumed by the Cloud part, we use a real server from the large-scale
|
|
test-bed Grid'5000. Grid'5000 provides clusters composed of several nodes which
|
|
are connected to wattmeters. The wattmeters provide 50
|
|
instantaneous power measurements per second and per server. This
|
|
way, we can benefit from real energy measurements. The server used
|
|
in the experiment embeds two Intel Xeon E5-2620 v4 processors with
|
|
64 GB of RAM and 600GB
|
|
of disk space on a Linux based operating system. This server is configured to use KVM as
|
|
virtualization mechanism. We deploy a classical Debian x86_64 distribution on the Virtual Machine
|
|
(VM) along with a MySQL database. We use different amounts of allocated memory for the VM namely
|
|
1024MB/2048MB/4096MB to highlight its effects on the server energy
|
|
consumption. The server only hosts this VM in order to easily isolate its
|
|
power consumption.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=0.45\linewidth]{./plots/g5k-xp.png}
|
|
\caption{Grid'5000 experimental setup.}
|
|
\label{fig:g5kExp}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
The data sent by the IoT devices are simulated using another
|
|
server from the same cluster. This server is in charge of sending
|
|
the data packets to the VM hosting the application in order to fill
|
|
its database. In the following, each data packet coming from an IoT
|
|
device and addressed to the application VM is called a request. Consequently, it is easy to vary the
|
|
different application characteristics namely: \textbf{1)} The number
|
|
of requests, to virtually
|
|
add/remove sensors \textbf{2)} The requests interval, to study the
|
|
impact of the transmitting frequency. Figure \ref{fig:g5kExp} presents this simulation
|
|
setup.
|
|
|
|
|
|
|
|
|
|
* Evaluation
|
|
#+LaTeX: \label{sec:eval}
|
|
In this section, we analyze the experimental results.
|
|
|
|
** IoT and Network Power Consumption
|
|
In a first place, we start by studying the impact of the sensors' transmission frequency on their
|
|
energy consumption. To this end, we run several simulations in ns3 with 15 sensors using
|
|
different transmission frequencies. The results provided by Table
|
|
\ref{tab:sensorsSendIntervalEffects} show that the transmission frequency has a very low impact
|
|
on the energy consumption and on the average end-to-end application delay. It has an impact of
|
|
course, but it is very limited. This due to the fact that in such a scenario with very small
|
|
number of communications spread over the time, sensors don't have to contend for accessing to the
|
|
Wifi channel.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
% Please add the following required packages to your document preamble:
|
|
% \usepackage{booktabs}
|
|
\begin{table*}[]
|
|
\centering
|
|
\caption{Sensors transmission interval effects with 15 sensors}
|
|
\label{tab:sensorsSendIntervalEffects}
|
|
\begin{tabular}{@{}lrrrrr@{}}
|
|
\toprule
|
|
Transmission Interval & 10s & 30s & 50s & 70s & 90s \\ \midrule
|
|
Sensor Power & 13.517\hl{94}W & 13.517\hl{67}W & 13.51767W & 13.51767W & 13.517\hl{61}W \\
|
|
Network Power & 0.441\hl{88}W & 0.441\hl{77}W & 0.44171W & 0.44171W & 0.441\hl{71}W \\
|
|
Application Delay & 0.09951s & 0.10021s & 0.10100s & 0.10203s & 0.10202s \\ \bottomrule
|
|
\end{tabular}
|
|
\end{table*}
|
|
#+END_EXPORT
|
|
|
|
|
|
Previous work \cite{li_end--end_2018} on a similar scenario shows that increasing application
|
|
accuracy impacts strongly the energy consumption in the context of data stream analysis. However,
|
|
in our case, application accuracy is driven by the sensing interval and thus, the transmission
|
|
frequency of the sensors.
|
|
In our case with small and sporadic network traffic, these results show that with a reasonable
|
|
transmission interval, the energy consumption of the IoT and the
|
|
network parts are almost not affected by the
|
|
variation of this transmission interval. In fact, transmitted data are not large enough to
|
|
leverage the energy consumed by the network.
|
|
|
|
We then vary the number of sensors in the Wifi cell.
|
|
The Figure \ref{fig:sensorsNumber} represents the energy consumed by each simulated part
|
|
according to the number of sensors. It is clear that the energy consumed by the network is the
|
|
dominant part. However, if the number of sensors is increasing, the energy consumed by the
|
|
network can become smaller than the sensors part. In fact, deploying new
|
|
sensors in the cell do not introduce much network load. To this end, sensors energy consumption
|
|
can become dominant.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=0.5\linewidth]{./plots/numberSensors-WIFINET.png}
|
|
\caption{Analysis of the variation of the number of sensors on the IoT/Network part energy consumption for a transmission interval of 10s.}
|
|
\label{fig:sensorsNumber}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
|
|
** Cloud Energy Consumption
|
|
In this end-to-end energy consumption study, cloud accounts for a huge part of the overall energy
|
|
consumption. According a report \cite{shehabi_united_2016-1} On United States data center energy
|
|
usage, the average Power Usage Effectiveness (PUE) of an hyper-scale data center is 1.2. Thus, in
|
|
our analysis, all energy measurement on cloud server will account
|
|
for this PUE. It means that the power consumption of the server is multiplied by
|
|
the PUE to include the external energy costs like server cooling
|
|
and data center facilities \cite{Ehsan}.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[width=0.8\linewidth]{./plots/vmSize-cloud.png}
|
|
\caption{Server power consumption multiplied by the PUE (= 1.2) using 20 sensors sending data every 10s for various VM memory sizes}
|
|
\label{fig:vmSize}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
|
|
Firstly, we analyze the impact of the VM allocated memory on the server energy
|
|
consumption. Figure \ref{fig:vmSize} depicts the server energy consumption according to the VM
|
|
allocated memory for 20 sensors sending data every 10s. Note that
|
|
the horizontal red line represents
|
|
the average energy consumption for the considered sample of energy values. We can see that at
|
|
each transmission interval, the server faces spikes of energy
|
|
consumption. However, the amount of allocated memory to the VM
|
|
does not significantly influence the server energy consumption. In
|
|
fact, simple database requests do not need any particular
|
|
heavy memory accesses and processing time. Thus, remaining experiments are based on VM with 1024MB
|
|
of allocated memory.
|
|
|
|
Next, we study the effects of increasing the number of sensors on the server energy consumption.
|
|
Figure \ref{fig:sensorsNumber-server} presents the results of the average server energy
|
|
consumption when varying the number of sensors from 20 to 500, while Figure
|
|
\ref{fig:sensorsNumber-WPS} presents the average server energy cost per sensor according to the
|
|
number of sensors. These results show a clear linear relation between the number of sensors and
|
|
the server energy consumption. Moreover, we can see that the more sensors we have per VM, the
|
|
more energy we can save. In fact, since the server's idle power
|
|
consumption is high (around 97 Watts), it is more
|
|
energy efficient to maximize the number of sensors per server. As shown on Figure
|
|
\ref{fig:sensorsNumber-WPS}, a significant amount of energy can be save when passing from 20 to
|
|
300 sensors per VM. Note that these measurements are not the row
|
|
measurements taken from the wattmeters: they include the PUE
|
|
but they are not shared among all the VMs that could be hosted on this
|
|
server. So, for the studied server, its static power consumption
|
|
(also called idle consumption) is around 83.2 Watts and we consider
|
|
a PUE of 1.2, this value is taken from \cite{shehabi_united_2016-1}}.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\subfigure[Average server energy consumption multiplied by the PUE (= 1.2)]{
|
|
\includegraphics[width=0.4\linewidth]{./plots/sensorsNumberLine-cloud.png}
|
|
\label{fig:sensorsNumber-server}
|
|
}
|
|
\hspace{0.5cm}
|
|
\subfigure[Average sensors energy cost on the server hosting only our VM]{
|
|
\includegraphics[width=0.4\linewidth]{./plots/WPS-cloud.png}
|
|
\label{fig:sensorsNumber-WPS}
|
|
}
|
|
\caption{Server energy consumption multiplied by the PUE (= 1.2) for sensors sending data every 10s}
|
|
\label{fig:sensorsNumber-cloud}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
A last parameter can leverage server energy consumption, namely
|
|
sensors transmission interval. In addition
|
|
to increasing the application accuracy, sensors transmission frequency increases network traffic and
|
|
database accesses. Figure \ref{fig:sensorsFrequency} presents the impact on the server energy
|
|
consumption when changing the transmission interval of 50 sensors
|
|
to 1s, 10s and 30s. We can see that, the lower sensors transmission
|
|
interval is, the more server energy consumption peaks
|
|
occur. Therefore, it leads to an increase of the server energy consumption.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics[scale=0.5]{plots/sendInterval-cloud.png}
|
|
\caption{Server energy consumption multiplied by the PUE (= 1.2) for 50 sensors sending requests at different transmission interval.}
|
|
\label{fig:sensorsFrequency}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
* End-To-End Consumption Model
|
|
#+LaTeX: \label{sec:discuss}
|
|
|
|
To have an overview of the energy consumed by the overall system, it is important to consider the
|
|
end-to-end energy consumption.
|
|
We detail here the model used to attribute the energy
|
|
consumption of our application for each part of the
|
|
architecture. For a given IoT device, we have:
|
|
1. For the IoT part, the entire consumption of the IoT device
|
|
belongs to the system's accounted consumption.
|
|
2. For the network part, the data packets generated by the IoT
|
|
device travel through network switches, routers and ports that
|
|
are shared with other trafic.
|
|
3. For the cloud part, the VM hosthing the data is shared with
|
|
other IoT devices belonging to the same application and the
|
|
server hosting the VM also hosts other VMs. Furthermore, the
|
|
server belongs to a data center and takes part in the overall
|
|
energy drawn to cool the server room.
|
|
|
|
Concerning the IoT part, we include the entire IoT device power
|
|
consumption. Indeed, in our targeted low-bandwidth IoT application,
|
|
the sensor is dedicated to this application. From Table 1, one can
|
|
derive that the static power
|
|
consumption of one IoT sensor is around 0.9 Watts. Its dynamic part
|
|
depends on the transmission frequency.
|
|
|
|
Concerning the sharing of the network costs, for each router, we
|
|
consider its aggregate bandwidth (on all the ports), its average
|
|
link utilization and the share taken by our IoT application. For a
|
|
given network device, we compute our share of the static energy
|
|
part as follows:
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\[P_{static}^{netdevice} = \frac{P_{static}^{device} \times Bandwidth^{application}}{AggregateBandwidth^{device}
|
|
\times LinkUtilization^{device}}\]
|
|
#+End_EXPORT
|
|
|
|
where $P_{static}^{device}$ is the static power consumption of the
|
|
network device (switch fabrics for instance or gateway),
|
|
$Bandwidth^{application }$ Is the bandwidth used by our IoT application,
|
|
$AggregateBandwidth^{device }$ is the overall aggregated bandwidth of the
|
|
network device on all its ports, and $LinkUtilization^{device}$ is the
|
|
effective link utilization percentage. The $Bandwidth^{application }$
|
|
depends on the transmission frequency in our use-case.
|
|
The formula includes the
|
|
link utilization in order to charge for the effective energy cost
|
|
per trafic and not for the theoretical upper bound which is the
|
|
link bandwidth. Indeed, using such an upper bound leads to greatly
|
|
underestimate our energy part, since link utilization typically
|
|
varies between 5 to 40% \cite{Hassidim2013,Zhang2016}.
|
|
|
|
Similarly, for each network port, we take the share attributable to
|
|
our application: the ratio of our bandwidth utilization over the
|
|
port bandwidth multiplied by the link utilization and the overall
|
|
static power consumption of the port. Table \ref{tab:netbidules}
|
|
summarizes the parameters used in our model, they are taken from
|
|
\cite{mahadevan_power_2009,Hassidim2013}. These are the parameters
|
|
used in our formula to compute the values that we used in the
|
|
simulations and that are presented in left part of Table 1.
|
|
|
|
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{table}[]
|
|
\centering
|
|
\caption{Network Devices Parameters}
|
|
\label{tab:netbidules}
|
|
\begin{tabular}{l|l}
|
|
Device & ~Parameters \\ \midrule
|
|
Gateway & ~Static power = 8.3 Watts, Bandwidth = 54Mbps, Utilization = 10\% \\
|
|
Core router & ~Static power = 555 Watts, 48 ports of 1 Gbps, Utilization = 25\% \\
|
|
Edge switch~ & ~Static power = 150 Watts, 48 ports of 1 Gbps, Utilization = 25\% \\
|
|
\bottomrule
|
|
\end{tabular}}
|
|
\end{table}
|
|
#+END_EXPORT
|
|
|
|
|
|
|
|
For the sharing of the Cloud costs, we take into account the number
|
|
of VMs that a server can host, the CPU utilization of a VM and the
|
|
PUE. For a given Cloud server hosting our IoT application, we
|
|
compute our share of the static energy part as follows:
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\[P_{static}^{Cloudserver} = \frac{P_{static}^{server} \times PUE^{DataCenter}}{HostedVMs^{server}}\]
|
|
#+End_EXPORT
|
|
|
|
Where $P_{static}^{server}$ is the static power consumption of the
|
|
server, $PUE^{DataCenter}$ is the data center PUE, and
|
|
$HostedVMs^{server}$ is the number of VMs a server can host. This last
|
|
parameter should be adjusted in the case of VMs with multiple
|
|
virtual CPUs. We do not
|
|
consider here over-commitment of Cloud servers. Yet, the dynamic
|
|
energy part is computed with the real dynamic measurements, so it
|
|
accounts for VM over-provisionning and resource under-utilization.
|
|
|
|
In our case, the Cloud server has 14 cores, which corresponds to
|
|
the potential hosting of 14 small VMs with one virtual CPU each,
|
|
and each vCPU is pinned to a server core. We consider that for
|
|
fault-tolerance purpose, the IoT application has a replication
|
|
factor of 2, meaning that two cloud servers store its database.
|
|
|
|
The Figure \ref{fig:end-to-end} represents the end-to-end system
|
|
energy consumption using the model described above while varying
|
|
the number of sensors for a transmission interval of 10
|
|
seconds. The values are extracted from the experiments presented in
|
|
the previous section.
|
|
|
|
#+BEGIN_EXPORT latex
|
|
\begin{figure}
|
|
\centering
|
|
\hspace{1cm}
|
|
\includegraphics[scale=0.35]{plots/final.png}
|
|
\label{fig:end-to-end}
|
|
\caption{End-to-end network energy consumption using sensors interval of 10s}
|
|
\end{figure}
|
|
#+END_EXPORT
|
|
|
|
|
|
Note that, for small-scale systems, with WiFi IoT devices, the IoT
|
|
sensor part is dominant in the overall energy consumption. Indeed,
|
|
the IoT application induces a very small cost on Cloud and network
|
|
infrastructures compared to the IoT device cost. But, our model
|
|
assumes that a single VM is handling multiple users (up to 300
|
|
sensors), thus being energy-efficient. Conclusions would be
|
|
different with one VM per user in the case of no over-commitment on
|
|
the Cloud side. For the network infrastructure, in our case of
|
|
low-bandwidth utilization (one data packet every 10 seconds), the
|
|
impact is almost negligible.
|
|
|
|
Another way of looking at these results is to observe that only for
|
|
a high number of sensors (more than 300), the power consumption of Cloud and
|
|
network parts start to be negligible (few percent). It means that,
|
|
if IoT applications handle clients one by one (i.e. one VM per
|
|
client), the impact is high on cloud and network part if they have
|
|
only few sensors. The energy efficiency is really poor for only few
|
|
devices: with 20 IoT sensors, the overall energy cost to handle these
|
|
devices is 2.5 times the energy consumption of the IoT devices
|
|
themselves. Instead of increasing the number of sensors, which
|
|
would result in a higher overall energy consumption, one should
|
|
focus on reducing the energy consumption of IoT devices, especially
|
|
WiFi devices which are common due to WiFi availability
|
|
everywhere. One could also focus on improving the energy cost of
|
|
Cloud and network infrastructure for low-bandwidth applications and
|
|
few devices.
|
|
|
|
|
|
|
|
* Conclusion
|
|
#+LaTeX: \label{sec:cl}
|
|
|
|
Information and Communication Technology takes a growing part in the
|
|
worldwide energy consumption. One of the root causes of this increase
|
|
lies in the multiplication of connected devices. Each object of the
|
|
Internet-of-Things often does not consume much energy by itself. Yet,
|
|
their number and the infrastructures they require to properly work
|
|
have leverage.
|
|
|
|
In this paper, we combine simulations and real
|
|
measurements to study the energy impact of IoT devices. In particular,
|
|
we analyze the energy consumption of Cloud and telecommunication
|
|
infrastructures induced by the utilization of connected devices.
|
|
Through the fine-grain analysis of a given low-bandwidth IoT device
|
|
periodically sending data to a Cloud server using WiFi,
|
|
we propose an end-to-end energy consumption model.
|
|
This model provides insights on the hidden part of the iceberg: the
|
|
impact of IoT devices on the energy consumption of Cloud and network
|
|
infrastructures. On our use-case, we show that for a given sensor, its
|
|
larger energy consumption is on the sensor part. But the impact on the
|
|
Cloud and network part is huge when using only few sensors with
|
|
low-bandwidth applications.
|
|
Consequently, with the
|
|
IoT exploding growth, it becomes necessary to improve the energy
|
|
efficiency of applications hosted on Cloud infrastructures and of IoT devices.
|
|
Our future work includes studying other types of IoT wireless
|
|
transmission techniques that would be more energy-efficient. We also
|
|
plan to study other
|
|
IoT applications in order to increase the applicability of our model
|
|
and provide advice for increasing the energy-efficiency of IoT infrastructures.
|
|
|
|
|
|
|
|
\bibliographystyle{IEEEtran}
|
|
\bibliography{references}
|
|
|
|
|
|
* Data Provenance :noexport:
|
|
:PROPERTIES:
|
|
:header-args: :eval never-export
|
|
:END:
|
|
** Data Analysis (R Scripts)
|
|
*** Utils
|
|
**** R
|
|
RUtils is intended to load logs (data.csv) and providing
|
|
simple plot function for them.
|
|
|
|
#+NAME: RUtils
|
|
#+BEGIN_SRC R :eval never
|
|
library("tidyverse")
|
|
|
|
# Fell free to update the following
|
|
labels=c(time="Time (s)",sensorsSendInterval="Sensors Send Interval (s)", sensorsNumber="Number of sensors")
|
|
PUE=1.2
|
|
ns3SimTime=1800
|
|
g5kSimTime=300
|
|
|
|
loadData=function(path){
|
|
data=read_csv(path)
|
|
if("sensorsEnergy"%in%colnames(data)){ # If it is ns3 logs
|
|
data=data%>%mutate(sensorsEnergy=sensorsEnergy/ns3SimTime) # Convert to watts
|
|
data=data%>%mutate(networkEnergy=networkEnergy/ns3SimTime)
|
|
data=data%>%mutate(networkEnergy=networkEnergy+getSwitchesIDLE(sensorsNumber,sensorsSendInterval)) # Add Idle conso of switches
|
|
data=data%>%mutate(totalEnergy=totalEnergy/ns3SimTime)
|
|
}
|
|
else{ # Log from g5k
|
|
data=data%>%mutate(energy=energy*PUE) # Take into account PUE
|
|
data=data%>%filter(time<=g5kSimTime) # Remove extrats values (theorical sim time != real sim time)
|
|
}
|
|
}
|
|
|
|
|
|
getSwitchesIDLE=function(nbSensors, sendInterval){
|
|
pktSize=192
|
|
nEdgeRouter=8
|
|
nCoreRouter=1
|
|
|
|
EdgeIdle=4095
|
|
EdgeMax=4550
|
|
EdgeTraffic=560*10^9
|
|
|
|
CoreIdle=11070
|
|
CoreMax=12300
|
|
CoreTraffic=4480*10^9
|
|
|
|
# Apply 0.6 factor
|
|
EdgeTraffic=EdgeTraffic*0.6
|
|
CoreTraffic=CoreTraffic*0.6
|
|
|
|
totalTraffic=pktSize/sendInterval*nbSensors
|
|
|
|
EdgeConso=EdgeIdle*(totalTraffic/EdgeTraffic)
|
|
CoreConso=CoreIdle*(totalTraffic/CoreTraffic)
|
|
|
|
return(EdgeConso+CoreConso)
|
|
}
|
|
|
|
# Get label according to varName
|
|
getLabel=function(varName){
|
|
if(is.na(labels[varName])){
|
|
return(varName)
|
|
}
|
|
return(labels[varName])
|
|
}
|
|
|
|
applyTheme=function(plot,...){
|
|
palette<- c("#00AFBB", "#E7B800", "#FC4E07","#0abb00")
|
|
plot=plot+
|
|
theme_bw(...)+
|
|
scale_fill_manual(values=palette)+
|
|
scale_colour_manual(values=palette)
|
|
return(plot)
|
|
}
|
|
|
|
#+END_SRC
|
|
|
|
|
|
|
|
**** Bash
|
|
***** Plots -> PDF
|
|
Merge all plots in plots/ folder into a pdf file.
|
|
#+NAME: plotToPDF
|
|
#+BEGIN_SRC bash :results output :noweb yes
|
|
orgFile="plots/plots.org"
|
|
<<singleRun>> # To get all default arguments
|
|
|
|
# Write helper function
|
|
function write {
|
|
echo "$1" >> $orgFile
|
|
}
|
|
|
|
echo "#+TITLE: Analysis" > $orgFile
|
|
write "#+LATEX_HEADER: \usepackage{fullpage}"
|
|
write "#+OPTIONS: toc:nil"
|
|
# Default arguments
|
|
write '\begin{center}'
|
|
write '\begin{tabular}{lr}'
|
|
write 'Parameters & Values\\'
|
|
write '\hline'
|
|
write "sensorsPktSize & ${sensorsPktSize} bytes\\\\"
|
|
write "sensorsSendInterval & ${sensorsSendInterval}s\\\\"
|
|
write "sensorsNumber & ${sensorsNumber}\\\\"
|
|
write "nbHop & ${nbHop}\\\\"
|
|
write "linksBandwidth & ${linksBandwidth}Mbps\\\\"
|
|
write "linksLatency & ${linksLatency}ms\\\\"
|
|
write '\end{tabular}'
|
|
write '\newline'
|
|
write '\end{center}'
|
|
|
|
for plot in $(find plots/ -type f -name "*.png")
|
|
do
|
|
write "\includegraphics[width=0.5\linewidth]{$(basename ${plot})}"
|
|
done
|
|
|
|
# Export to pdf
|
|
emacs $orgFile --batch -f org-latex-export-to-pdf --kill
|
|
#+END_SRC
|
|
|
|
***** CSVs -> data.csv (G5K)
|
|
Merge all energy file into one (and add additional fields).
|
|
|
|
#+NAME: G5K-mergeCSV
|
|
#+BEGIN_SRC sh
|
|
#!/bin/bash
|
|
|
|
whichLog="last"
|
|
|
|
logsLocation="logs/g5k"
|
|
whichLog="${logsLocation}/${whichLog}"
|
|
|
|
|
|
|
|
logFile="$(dirname $(readlink -f $0))"/$whichLog/simLogs.txt
|
|
dataFile=$(dirname "$logFile")/data.csv
|
|
|
|
|
|
getValue () {
|
|
line=$(echo "$1" | grep "Simulation para"|sed "s/Simulation parameters: //g")
|
|
key=$2
|
|
echo "$line"|awk 'BEGIN{RS=" ";FS=":"}"'$key'"==$1{gsub("\n","",$0);print $2}'
|
|
}
|
|
|
|
##### Add extract info to energy #####
|
|
IFS=$'\n'
|
|
for cmd in $(cat $logFile|grep "Simulation parameters")
|
|
do
|
|
nodeName=$(getValue $cmd serverNodeName)
|
|
from=$(getValue $cmd simStart)
|
|
to=$(getValue $cmd simEnd)
|
|
vmSize=$(getValue $cmd vmSize)
|
|
nbSensors=$(getValue $cmd nbSensors)
|
|
simKey=$(getValue $cmd simKey)
|
|
sendInterval=$(getValue $cmd sensorsSendInterval)
|
|
csvFile="$whichLog/${simKey}_${vmSize}VMSIZE_${nbSensors}NBSENSORS_${from}${to}.csv"
|
|
csvFileIDLE="$whichLog/${simKey}_${vmSize}VMSIZE_${nbSensors}NBSENSORS_${from}${to}_IDLE.csv"
|
|
tmpFile=${csvFile}_tmp
|
|
echo ts,energy,simKey,vmSize,nbSensors,time,state,sendInterval > $tmpFile
|
|
minTs=$(tail -n+2 $csvFile|awk -F"," 'BEGIN{min=0}$1<min||min==0{min=$1}END{print(min)}') # To compute ts field
|
|
minTsIDLE=$(tail -n+2 $csvFileIDLE|awk -F"," 'BEGIN{min=0}$1<min||min==0{min=$1}END{print(min)}') # To compute ts field
|
|
tail -n+2 ${csvFile} | awk -F"," '{print $0",'$simKey','$vmSize','$nbSensors',"$1-'$minTs'",sim,"'$sendInterval'}' >> $tmpFile
|
|
tail -n+2 ${csvFileIDLE} | awk -F"," '{print $0",'$simKey','$vmSize','$nbSensors',"$1-'$minTsIDLE'",IDLE,"'$sendInterval'}' >> $tmpFile
|
|
done
|
|
|
|
|
|
##### Fill dataFile #####
|
|
echo ts,energy,simKey,vmSize,nbSensors,time,state,sendInterval > $dataFile
|
|
for tmpFile in $(find ${whichLog}/*_tmp -type f)
|
|
do
|
|
tail -n+2 $tmpFile >> $dataFile
|
|
rm $tmpFile # Pay attention to this line :D
|
|
done
|
|
#+END_SRC
|
|
|
|
#+RESULTS: G5K-mergeCSV
|
|
|
|
#+RESULTS: mergeCSV
|
|
|
|
|
|
|
|
***** Log -> data.csv (ns3)
|
|
logToCSV extract usefull data from logs and put them into logs/data.csv.
|
|
|
|
#+NAME: NS3-logToCSV
|
|
#+BEGIN_SRC bash :results output
|
|
logsFolder="./logs/ns3/last/"
|
|
csvOutput="$logsFolder/data.csv"
|
|
|
|
# First save csv header line
|
|
aLog=$(find $logsFolder -type f -name "*.org"|head -n 1)
|
|
metrics=$(cat $aLog|grep "\-METRICSLINE\-"|sed "s/-METRICSLINE-//g")
|
|
echo $metrics | awk '{for(i=1;i<=NF;i++){split($i,elem,":");printf(elem[1]);if(i<NF)printf(",");else{print("")}}}' > $csvOutput
|
|
|
|
# Second save all values
|
|
for logFile in $(find $logsFolder -type f -name "*.org")
|
|
do
|
|
metrics=$(cat $logFile|grep "\-METRICSLINE\-"|sed "s/-METRICSLINE-//g")
|
|
echo $metrics | awk '{for(i=1;i<=NF;i++){split($i,elem,":");printf(elem[2]);if(i<NF)printf(",");else{print("")}}}' >> $csvOutput
|
|
done
|
|
#+END_SRC
|
|
|
|
#+RESULTS: NS3-logToCSV
|
|
|
|
|
|
|
|
|
|
|
|
*** Plot Scripts
|
|
**** Random R Scripts
|
|
|
|
Table sensorsSendInterval~Sensors+NetEnergyconsumption
|
|
#+BEGIN_SRC R :noweb yes :results output
|
|
<<RUtils>>
|
|
|
|
data=loadData("logs/ns3/last/data.csv")
|
|
sensorsE=data%>%filter(simKey=="SENDINTERVAL",sensorsNumber==15) %>%select(sensorsSendInterval,sensorsEnergy)%>%arrange(sensorsSendInterval)
|
|
delay=data%>%filter(simKey=="SENDINTERVAL",sensorsNumber==15) %>%select(sensorsSendInterval,avgDelay)%>%arrange(sensorsSendInterval)
|
|
netE=data%>%filter(simKey=="SENDINTERVAL",sensorsNumber==15) %>%select(sensorsSendInterval,networkEnergy)%>%arrange(sensorsSendInterval)
|
|
formatData=right_join(sensorsE,netE)%>%right_join(delay)%>%filter(((sensorsSendInterval/10)%%2)!=0)
|
|
|
|
print(t(formatData))
|
|
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
: [,1] [,2] [,3] [,4] [,5]
|
|
: sensorsSendInterval 10.0000000 30.000000 50.000000 70.000000 90.000000
|
|
: sensorsEnergy 13.5179444 13.517667 13.517667 13.517667 13.517611
|
|
: networkEnergy 10.4417825 10.441668 10.441612 10.441612 10.441612
|
|
: avgDelay 0.0995173 0.100214 0.101002 0.102034 0.102025
|
|
|
|
|
|
|
|
|
|
Figure Sensors Position ~ Energy/Delay
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sensorsPosition-delayenergy.png
|
|
<<RUtils>>
|
|
tr=11 # Offset to center delay plot
|
|
data=loadData("logs/ns3/last/data.csv")
|
|
|
|
data=data%>%filter(simKey=="SENSORSPOS",sensorsNumber==9)
|
|
|
|
p=ggplot(data,aes(y=sensorsEnergy,x=positionSeed,color="Energy"))+xlab(getLabel("Sensors Position Seed"))+ylab(getLabel("Sensors Power Consumption (W)"))+
|
|
geom_line()+geom_point()+geom_line(aes(y=(avgDelay-tr),color="Delay"))+geom_point(aes(y=(avgDelay-tr),color="Delay"))+expand_limits(y=c(0,15))+
|
|
scale_y_continuous(sec.axis = sec_axis(~.+tr, name = "Application Delay (s)")) +
|
|
guides(color=guide_legend(title="Curves"))
|
|
|
|
p=applyTheme(p)
|
|
p=p+theme(axis.title.y.right = element_text(margin = margin(t = 0, r = -8, b = 0, l = 10)))
|
|
|
|
|
|
|
|
ggsave("plots/sensorsPosition-delayenergy.png",dpi=80, width=4, height=3.2)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/sensorsPosition-delayenergy.png]]
|
|
|
|
|
|
|
|
Watt per sensor on server
|
|
#+BEGIN_SRC R :noweb yes :results output
|
|
<<RUtils>>
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="nbSensors")%>%ungroup()
|
|
|
|
|
|
data=data%>%group_by(nbSensors)%>%mutate(avgEnergy=mean(energy))%>%distinct()%>%ungroup()
|
|
data=data%>%distinct(nbSensors,.keep_all=TRUE)
|
|
data=data%>%mutate(WPS=(avgEnergy/nbSensors))
|
|
|
|
print(data%>%select(WPS,nbSensors))
|
|
#+END_SRC
|
|
|
|
|
|
|
|
Impact of vm size
|
|
#+BEGIN_SRC R :results graphics :file plots/vmSizeBar-cloud.png
|
|
library("tidyverse")
|
|
PUE=1.2
|
|
# Load data
|
|
data=read_csv("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="vmSize")%>%mutate(energy=PUE*energy)%>%filter(time<=300)
|
|
|
|
data=data%>%group_by(vmSize)%>%mutate(energy=mean(energy))%>%slice(1L)%>%ungroup()
|
|
data=data%>%mutate(vmSize=as.character(vmSize))
|
|
|
|
ggplot(data) + geom_bar(aes(x=vmSize,y=energy),stat="identity")+expand_limits(y=c(75,100))+ylab("Server Power Consumption (W)")+
|
|
xlab("Experiment Time (s)")+scale_y_log10()
|
|
|
|
|
|
ggsave("plots/vmSizeBar-cloud.png",dpi=90,height=3,width=6)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/vmSizeBar-cloud.png]]
|
|
|
|
|
|
|
|
#+NAME: ssiNet
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sensorsSendInterval-net.png
|
|
<<NS3-RUtils>>
|
|
# Load Data
|
|
data=read_csv("logs/ns3/last/data.csv")
|
|
|
|
data%>%filter(simKey=="SENDINTERVAL",sensorsNumber==20) %>% ggplot(aes(x=sensorsSendInterval,y=networkEnergy))+xlab(getLabel("sensorsSendInterval"))+ylab(getLabel("networkEnergy"))+
|
|
geom_line()+labs(title="For 20 sensors")
|
|
ggsave("plots/sensorsSendInterval-net.png",dpi=80)
|
|
#+END_SRC
|
|
|
|
|
|
Effect of the number of sensors on the application delay
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/delay-nbsensors.png
|
|
<<NS3-RUtils>>
|
|
# Load Data
|
|
data=read_csv("logs/ns3/last/data.csv")
|
|
|
|
data%>%filter(simKey=="NBSENSORS") %>% ggplot(aes(y=avgDelay,x=sensorsNumber))+xlab(getLabel("sensorsNumber"))+ylab(getLabel("avgDelay"))+
|
|
geom_line()+labs(title="For 20 sensors")
|
|
ggsave("plots/delay-nbsensors.png",dpi=80)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/delay-nbsensors.png]]
|
|
|
|
|
|
|
|
#+NAME: ssiWifi
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sensorsSendInterval-wifi.png
|
|
<<NS3-RUtils>>
|
|
data=read_csv("logs/ns3/last/data.csv")
|
|
data%>%filter(simKey=="SENDINTERVAL",sensorsNumber==20) %>% ggplot(aes(x=sensorsSendInterval,y=sensorsEnergy))+xlab(getLabel("sensorsSendInterval"))+ylab(getLabel("sensorsEnergy"))+
|
|
geom_line() + geom_line()+labs(title="For 20 sensors")
|
|
ggsave("plots/sensorsSendInterval-wifi.png",dpi=80)
|
|
#+END_SRC
|
|
|
|
|
|
#+BEGIN_SRC R :results graphics :noweb yes :file plots/plot-final.png :session *R*
|
|
<<NS3-RUtils>>
|
|
simTime=1800
|
|
|
|
# Network
|
|
data=read_csv("logs/ns3/last/data.csv")
|
|
data=data%>%filter(simKey=="NBSENSORS")
|
|
dataC5=data%>%filter(sensorsNumber==5)%>% mutate(energy=networkEnergy/simTime) %>%select(energy,sensorsNumber)
|
|
dataC10=data%>%filter(sensorsNumber==10)%>%mutate(energy=networkEnergy/simTime) %>%select(energy,sensorsNumber)
|
|
dataNet=rbind(dataC5,dataC10)%>%mutate(type="Network")
|
|
|
|
# Network
|
|
dataS5=data%>%filter(sensorsNumber==5)%>% mutate(energy=sensorsEnergy/simTime) %>%select(energy,sensorsNumber)
|
|
dataS10=data%>%filter(sensorsNumber==10)%>%mutate(energy=sensorsEnergy/simTime) %>%select(energy,sensorsNumber)
|
|
dataS=rbind(dataS5,dataS10)%>%mutate(type="Sensors")
|
|
|
|
data=rbind(dataNet,dataS)%>%mutate(sensorsNumber=as.character(sensorsNumber))
|
|
|
|
ggplot(data)+geom_bar(aes(x=sensorsNumber,y=energy,fill=type),stat="identity")+xlab("Sensors Number")+ylab("Power Consumption (W)")+guides(fill=guide_legend(title="Part"))
|
|
ggsave("plots/plot-final.png",dpi=80)
|
|
|
|
#+END_SRC
|
|
|
|
**** Plot In Paper
|
|
|
|
Power sensors vs network
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/numberSensors-WIFINET.png :session *R*
|
|
<<RUtils>>
|
|
|
|
data=loadData("logs/ns3/last/data.csv")
|
|
data=data%>%filter(simKey=="NBSENSORS")
|
|
dataW=data%>%mutate(energy=sensorsEnergy)%>% mutate(type="Sensors") %>% select(sensorsNumber,energy,type)
|
|
dataN=data%>%mutate(energy=networkEnergy)%>% mutate(type="Network") %>% select(sensorsNumber,energy,type)
|
|
|
|
data=rbind(dataN,dataW)
|
|
data=data%>%mutate(sensorsNumber=as.character(sensorsNumber))
|
|
data=data%>%mutate(sensorsNumber=fct_reorder(sensorsNumber,as.numeric(sensorsNumber)))
|
|
data=data%>%filter(sensorsNumber%in%c(2,4,6,8,10))
|
|
|
|
p=ggplot(data)+geom_bar(aes(x=sensorsNumber,y=energy,fill=type),position="dodge",stat="identity")+
|
|
xlab(getLabel("sensorsNumber"))+ ylab("Power Consumption (W)") + guides(fill=guide_legend(title=""))
|
|
p=applyTheme(p)+theme(text = element_text(size=15))
|
|
|
|
size=5
|
|
ggsave("plots/numberSensors-WIFINET.png",dpi=90,width=size,height=size-1)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/numberSensors-WIFINET.png]]
|
|
|
|
|
|
Final plot: Energy cloud, network and sensors
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/final.png
|
|
<<RUtils>>
|
|
|
|
# Linear Approx
|
|
approx=function(data1, data2,nbSensors){
|
|
x1=data1$sensorsNumber
|
|
y1=data1$energy
|
|
|
|
x2=data2$sensorsNumber
|
|
y2=data2$energy
|
|
|
|
a=((y2-y1)/(x2-x1))
|
|
b=y1-a*x1
|
|
|
|
return(a*nbSensors+b)
|
|
|
|
}
|
|
|
|
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
data=data%>%filter(state=="sim",simKey=="nbSensors")
|
|
|
|
# Cloud
|
|
data=data%>%mutate(sensorsNumber=nbSensors)
|
|
data20=data%>%filter(nbSensors==20)%>%mutate(energy=mean(energy)) %>% slice(1L)
|
|
data100=data%>%filter(nbSensors==100)%>%mutate(energy=mean(energy)) %>% slice(1L)
|
|
data300=data%>%filter(nbSensors==300)%>%mutate(energy=mean(energy)) %>% slice(1L)
|
|
dataCloud=rbind(data20,data100,data300)%>%mutate(sensorsNumber=nbSensors)%>%mutate(type="Cloud")%>%select(sensorsNumber,energy,type)
|
|
dataCloud=bind_rows(dataCloud,tibble(sensorsNumber=1,energy=approx(data20,data100,1),type="Cloud"))
|
|
dataCloud=dataCloud%>%mutate(energy=energy/7) # Divide by 7 because 14 core so 1 machine can host 14 vm but we use redundancy (2VM for 1app)
|
|
|
|
# Network
|
|
data=loadData("./logs/ns3/last/data.csv")
|
|
data=data%>%filter(simKey=="NBSENSORS")
|
|
dataN5=data%>%filter(sensorsNumber==5)%>% mutate(energy=networkEnergy) %>%select(energy,sensorsNumber)
|
|
dataN10=data%>%filter(sensorsNumber==10)%>%mutate(energy=networkEnergy) %>%select(energy,sensorsNumber)
|
|
dataNet=rbind(dataN5,dataN10)
|
|
fakeNet=tibble(sensorsNumber=c(1,20,100,300))
|
|
fakeNet=fakeNet%>%mutate(energy=approx(dataN5,dataN10,sensorsNumber),type="Network")
|
|
|
|
# Sensors
|
|
dataS5=data%>%filter(sensorsNumber==5)%>% mutate(energy=sensorsEnergy) %>%select(energy,sensorsNumber)
|
|
dataS10=data%>%filter(sensorsNumber==10)%>%mutate(energy=sensorsEnergy) %>%select(energy,sensorsNumber)
|
|
dataS=rbind(dataS5,dataS10)
|
|
fakeS=tibble(sensorsNumber=c(1,20,100,300))
|
|
fakeS=fakeNet%>%mutate(energy=approx(dataS5,dataS10,sensorsNumber),type="Sensors")
|
|
|
|
# Combine Net/Sensors/Cloud and order factors
|
|
fakeData=rbind(fakeNet,fakeS,dataCloud)
|
|
fakeData=fakeData%>%mutate(sensorsNumber=as.character(sensorsNumber))
|
|
fakeData=fakeData%>%mutate(sensorsNumber=fct_reorder(sensorsNumber,as.numeric(sensorsNumber)))
|
|
fakeData$type=factor(fakeData$type,ordered=TRUE,levels=c("Sensors","Network","Cloud"))
|
|
|
|
# Plot
|
|
p=ggplot(fakeData)+geom_bar(position="dodge2",colour="black",aes(x=sensorsNumber,y=energy,fill=type),stat="identity")+
|
|
xlab("Sensors Number")+ylab("Power Consumption (W)")+guides(fill=guide_legend(title="System Part"))
|
|
p=applyTheme(p)+theme(text = element_text(size=16))
|
|
ggsave("plots/final.png",dpi=90,width=8,height=5.5)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/final.png]]
|
|
|
|
|
|
Impact of vm size
|
|
#+BEGIN_SRC R :noweb yes :results graphics :noweb yes :file plots/vmSize-cloud.png
|
|
<<RUtils>>
|
|
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="vmSize")%>%filter(time<=300)
|
|
|
|
data=data%>%mutate(vmSize=paste0(vmSize," MB"))
|
|
data=data%>%group_by(vmSize)%>%mutate(avgEnergy=mean(energy))%>%ungroup()
|
|
p=ggplot(data,aes(x=time, y=energy)) + geom_line()+facet_wrap(~vmSize)+geom_hline(aes(yintercept=avgEnergy),color="Red",size=1.0)+expand_limits(y=c(0,40))+ylab("Server Power Consumption (W)")+
|
|
xlab("Experiment Time (s)")
|
|
|
|
p=applyTheme(p)
|
|
|
|
ggsave("plots/vmSize-cloud.png",dpi=90,height=3,width=6)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/vmSize-cloud.png]]
|
|
|
|
|
|
Impact of sensors number
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sensorsNumber-cloud.png
|
|
<<RUtils>>
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="nbSensors")%>%ungroup()
|
|
|
|
data=data%>%mutate(nbSensorsSort=nbSensors)
|
|
data=data%>%mutate(nbSensors=paste0(nbSensors," Sensors"))
|
|
data$nbSensors=fct_reorder(data$nbSensors, data$nbSensorsSort)
|
|
|
|
data=data%>%group_by(nbSensors)%>%mutate(avgEnergy=mean(energy))%>%ungroup()
|
|
p=ggplot(data,aes(x=time, y=energy)) + geom_line()+facet_wrap(~nbSensors)+expand_limits(y=c(0,40))+ylab("Server Power Consumption (W)")+
|
|
xlab("Experiment Time (s)")+geom_hline(aes(yintercept=avgEnergy),color="Red",size=1.0)
|
|
|
|
p=applyTheme(p)
|
|
ggsave("plots/sensorsNumber-cloud.png",dpi=90,height=3,width=6)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/sensorsNumber-cloud.png]]
|
|
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sensorsNumberLine-cloud.png :session *R:2*
|
|
<<RUtils>>
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="nbSensors")%>%ungroup()
|
|
|
|
|
|
data=data%>%group_by(nbSensors)%>%mutate(avgEnergy=mean(energy))%>%distinct()%>%ungroup()
|
|
data=data%>%distinct(nbSensors,.keep_all=TRUE)
|
|
data=data%>%mutate(WPS=(avgEnergy/nbSensors))
|
|
|
|
p=ggplot(data,aes(x=nbSensors, y=avgEnergy)) + geom_point() +geom_line()+
|
|
xlab(getLabel("sensorsNumber"))+ylab("Average server power consumption (W)")
|
|
|
|
p=applyTheme(p)+theme(text = element_text(size=14))+ expand_limits(y=108)
|
|
ggsave("plots/sensorsNumberLine-cloud.png",dpi=90,height=4.5,width=4)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/sensorsNumberLine-cloud.png]]
|
|
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/WPS-cloud.png :session *R:2*
|
|
<<RUtils>>
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="nbSensors")%>%ungroup()
|
|
|
|
|
|
data=data%>%group_by(nbSensors)%>%mutate(avgEnergy=mean(energy))%>%distinct()%>%ungroup()
|
|
data=data%>%distinct(nbSensors,.keep_all=TRUE)
|
|
data=data%>%mutate(WPS=(avgEnergy/nbSensors))
|
|
|
|
oldNb=data$nbSensors
|
|
data=data%>%mutate(nbSensors=as.character(nbSensors))
|
|
data$nbSensors=fct_reorder(data$nbSensors,oldNb)
|
|
p=ggplot(data,aes(x=nbSensors, y=WPS)) + geom_bar(stat="identity")+
|
|
xlab(getLabel("sensorsNumber"))+ylab("Server power cost per sensors (W)")
|
|
|
|
p=applyTheme(p)+theme(text = element_text(size=14))+ theme(axis.title.y = element_text(margin = margin(t = 0, r = 8, b = 0, l = 0)))
|
|
ggsave("plots/WPS-cloud.png",dpi=90,height=4,width=4)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/WPS-cloud.png]]
|
|
|
|
#+BEGIN_SRC R :noweb yes :results graphics :file plots/sendInterval-cloud.png
|
|
<<RUtils>>
|
|
# Load data
|
|
data=loadData("./logs/g5k/last/data.csv")
|
|
|
|
data=data%>%filter(state=="sim",simKey=="sendInterval")%>%ungroup()
|
|
|
|
oldSendInterval=data$sendInterval
|
|
data=data%>%mutate(sendInterval=paste0(sendInterval,"s"))
|
|
data$sendInterval=fct_reorder(data$sendInterval,oldSendInterval)
|
|
|
|
data=data%>%group_by(sendInterval)%>%mutate(avgEnergy=mean(energy))%>%ungroup()
|
|
print(data)
|
|
p=ggplot(data,aes(x=time, y=energy)) + geom_line()+facet_wrap(~sendInterval)+expand_limits(y=c(0,40))+ylab("Server power consumption (W)")+
|
|
xlab("Experiment Time (s)")+geom_hline(aes(yintercept=avgEnergy),color="Red",size=1.0)
|
|
|
|
p=applyTheme(p)
|
|
ggsave("plots/sendInterval-cloud.png",dpi=120,height=3,width=6)
|
|
#+END_SRC
|
|
|
|
#+RESULTS:
|
|
[[file:plots/sendInterval-cloud.png]]
|
|
|
|
|
|
* Emacs settings :noexport:
|
|
# Local Variables:
|
|
# eval: (unless (boundp 'org-latex-classes) (setq org-latex-classes nil))
|
|
# eval: (add-to-list 'org-latex-classes
|
|
# '("llncs" "\\documentclass[conference]{llncs}\n \[NO-DEFAULT-PACKAGES]\n \[EXTRA]\n" ("\\section{%s}" . "\\section*{%s}") ("\\subsection{%s}" . "\\subsection*{%s}") ("\\subsubsection{%s}" . "\\subsubsection*{%s}") ("\\paragraph{%s}" . "\\paragraph*{%s}") ("\\subparagraph{%s}" . "\\subparagraph*{%s}")))
|
|
# End:
|
|
|
|
|
|
|