mirror of
https://gitlab.com/manzerbredes/paper-lowrate-iot.git
synced 2025-04-19 04:09:43 +00:00
version soumise
This commit is contained in:
parent
13278c78d3
commit
de531ec263
2 changed files with 4 additions and 4 deletions
|
@ -409,9 +409,9 @@ and transmission technologies.
|
||||||
|
|
||||||
* Evaluation
|
* Evaluation
|
||||||
#+LaTeX: \label{sec:eval}
|
#+LaTeX: \label{sec:eval}
|
||||||
In this section, we analyze the experimental results.
|
|
||||||
|
|
||||||
** IoT and Network Power Consumption
|
** IoT and Network Power Consumption
|
||||||
|
In this section, we analyze the experimental results.
|
||||||
In a first place, we start by studying the impact of the sensors' transmission frequency on their
|
In a first place, we start by studying the impact of the sensors' transmission frequency on their
|
||||||
energy consumption. To this end, we run several simulations in ns3 with 15 sensors using
|
energy consumption. To this end, we run several simulations in ns3 with 15 sensors using
|
||||||
different transmission frequencies. The results provided by Table
|
different transmission frequencies. The results provided by Table
|
||||||
|
@ -562,8 +562,8 @@ In our case with small and sporadic network traffic, these results show that wit
|
||||||
belongs to the system's accounted consumption.
|
belongs to the system's accounted consumption.
|
||||||
2. For the network part, the data packets generated by the IoT
|
2. For the network part, the data packets generated by the IoT
|
||||||
device travel through network switches, routers and ports that
|
device travel through network switches, routers and ports that
|
||||||
are shared with other trafic.
|
are shared with other traffic.
|
||||||
3. For the cloud part, the VM hosthing the data is shared with
|
3. For the cloud part, the VM hosting the data is shared with
|
||||||
other IoT devices belonging to the same application and the
|
other IoT devices belonging to the same application and the
|
||||||
server hosting the VM also hosts other VMs. Furthermore, the
|
server hosting the VM also hosts other VMs. Furthermore, the
|
||||||
server belongs to a data center and takes part in the overall
|
server belongs to a data center and takes part in the overall
|
||||||
|
@ -645,7 +645,7 @@ In our case with small and sporadic network traffic, these results show that wit
|
||||||
virtual CPUs. We do not
|
virtual CPUs. We do not
|
||||||
consider here over-commitment of Cloud servers. Yet, the dynamic
|
consider here over-commitment of Cloud servers. Yet, the dynamic
|
||||||
energy part is computed with the real dynamic measurements, so it
|
energy part is computed with the real dynamic measurements, so it
|
||||||
accounts for VM over-provisionning and resource under-utilization.
|
accounts for VM over-provisioning and resource under-utilization.
|
||||||
|
|
||||||
In our case, the Cloud server has 14 cores, which corresponds to
|
In our case, the Cloud server has 14 cores, which corresponds to
|
||||||
the potential hosting of 14 small VMs with one virtual CPU each,
|
the potential hosting of 14 small VMs with one virtual CPU each,
|
||||||
|
|
BIN
2019-ICA3PP.pdf
BIN
2019-ICA3PP.pdf
Binary file not shown.
Loading…
Add table
Add a link
Reference in a new issue