Merge branch 'master' of gitlab.inria.fr:lguegan/paper-lowrate-iot

This commit is contained in:
ORGERIE Anne-Cecile 2019-07-19 13:17:43 +02:00
commit 13278c78d3
4 changed files with 4 additions and 3 deletions

View file

@ -623,7 +623,7 @@ In our case with small and sporadic network traffic, these results show that wit
Core router & ~Static power = 555 Watts, 48 ports of 1 Gbps, Utilization = 25\% \\
Edge switch~ & ~Static power = 150 Watts, 48 ports of 1 Gbps, Utilization = 25\% \\
\bottomrule
\end{tabular}}
\end{tabular}
\end{table}
#+END_EXPORT
@ -688,7 +688,7 @@ In our case with small and sporadic network traffic, these results show that wit
client), the impact is high on cloud and network part if they have
only few sensors. The energy efficiency is really poor for only few
devices: with 20 IoT sensors, the overall energy cost to handle these
devices is 2.5 times the energy consumption of the IoT devices
devices is almost doubled compared to the energy consumption of the IoT devices
themselves. Instead of increasing the number of sensors, which
would result in a higher overall energy consumption, one should
focus on reducing the energy consumption of IoT devices, especially
@ -762,6 +762,7 @@ and provide advice for increasing the energy-efficiency of IoT infrastructures.
if("sensorsEnergy"%in%colnames(data)){ # If it is ns3 logs
data=data%>%mutate(sensorsEnergy=sensorsEnergy/ns3SimTime) # Convert to watts
data=data%>%mutate(networkEnergy=networkEnergy/ns3SimTime)
data=data%>%mutate(networkEnergy=networkEnergy-9.9999) # Anne-Cécile Factor (accounting for port idle (in fact we are not using all the 1W, there is also other communication on ISP switches)
data=data%>%mutate(networkEnergy=networkEnergy+getSwitchesIDLE(sensorsNumber,sensorsSendInterval)) # Add Idle conso of switches
data=data%>%mutate(totalEnergy=totalEnergy/ns3SimTime)
}
@ -1105,7 +1106,7 @@ and provide advice for increasing the energy-efficiency of IoT infrastructures.
**** Plot In Paper
Power sensors vs network
#+BEGIN_SRC R :noweb yes :results graphics :file plots/numberSensors-WIFINET.png :session *R*
#+BEGIN_SRC R :noweb yes :results graphics :file plots/numberSensors-WIFINET.png :session *R*
<<RUtils>>
data=loadData("logs/ns3/last/data.csv")

BIN
2019-ICA3PP.pdf Normal file

Binary file not shown.

Binary file not shown.

Before

Width:  |  Height:  |  Size: 21 KiB

After

Width:  |  Height:  |  Size: 21 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 15 KiB

After

Width:  |  Height:  |  Size: 15 KiB