modifs conso net

This commit is contained in:
ORGERIE Anne-Cecile 2019-07-19 11:38:43 +02:00
parent 3d6ecdd1ba
commit b2adf2caf0

View file

@ -299,7 +299,6 @@ and transmission technologies.
* Experimental setup
\hl{Ajouter \% de bande passante utilisé par les applis low-rate}
#+Latex: \label{sec:model}
In this section, we describe the experimental setup employed to
acquire energy measurements for each of the three parts of our
@ -346,7 +345,7 @@ and transmission technologies.
\label{tab:net-energy}
\begin{tabular}{@{}lr@{}}
Parameter & Value \\ \midrule
Idle & 1W \\
Idle & 0.00001W \\
Bytes (Tx/Rx) & 3.4nJ \\
Pkt (Tx/Rx) & 192.0nJ \\ \bottomrule
\end{tabular}
@ -427,14 +426,14 @@ In this section, we analyze the experimental results.
% \usepackage{booktabs}
\begin{table*}[]
\centering
\caption{Sensors transmission interval effects}
\caption{Sensors transmission interval effects with 15 sensors}
\label{tab:sensorsSendIntervalEffects}
\begin{tabular}{@{}lrrrrr@{}}
\toprule
Sensors Send Interval & 10s & 30s & 50s & 70s & 90s \\ \midrule
Sensors Power Consumption & 13.517\hl{94}W & 13.517\hl{67}W & 13.51767W & 13.51767W & 13.517\hl{61}W \\
Network Power Consumption & 10.441\hl{78}W & 10.441\hl{67}W & 10.44161W & 10.44161W & 10.441\hl{61}W \\
End-to-end Application Delay & 0.09951s & 0.10021s & 0.10100s & 0.10203s & 0.10202s \\ \bottomrule
Transmission Interval & 10s & 30s & 50s & 70s & 90s \\ \midrule
Sensor Power & 13.517\hl{94}W & 13.517\hl{67}W & 13.51767W & 13.51767W & 13.517\hl{61}W \\
Network Power & 0.441\hl{88}W & 0.441\hl{77}W & 0.44171W & 0.44171W & 0.441\hl{71}W \\
Application Delay & 0.09951s & 0.10021s & 0.10100s & 0.10203s & 0.10202s \\ \bottomrule
\end{tabular}
\end{table*}
#+END_EXPORT