##### Network Communications # ZMQ_PORT is the port used for all communications ZMQ_PORT=5556 # SUBSCRIBER_ADDR is used by the publishers # to contact the subscriber SUBSCRIBER_ADDR=10.128.0.133 # ZMQ_TOKEN is used by ZeroMQ to detect # messages from publishers. Leave as is if not sure. ZMQ_TOKEN=ina260-zmq-publisher # ZMQ_MSG_SIZE max number of bytes per ZeroMQ messages # Be careful with this parameter. Default is 5MiB # Units is bytes ZMQ_MSG_SIZE=5242880 ##### Publishers/Subscriber # LOG_DELAY defines the delay between 2 consecutive # ina260 power read performed by the logger # Unit is milliseconds LOG_DELAY=0 # SUBSCRIBER_DIR will contain all the measurments # received from the publishers SUBSCRIBER_DIR=./data # LOG_INTERVAL determined the duration # of a logging period. At the end of a logging period, # all the measurements are send by a publisher thread # Unit is seconds LOG_INTERVAL=20 # KEY is attached to all the messages published to the subscriber # It allows you to filter the messages on the publisher # if you are using multiple monitoring nodes (multiple publishers) KEY=node1 # MAX_QUEUE Maximum number of queues to use per publisher. # It allows the zmq thread to send the power measurements to the subscriber meanwhile # other measurements are collected. If only 1 queue is used, power measurements can # potentially be missing since parallelism is broken. MAX_QUEUE=2